Commercial buildings cover a wide spread of power needs. A boutique hotel or small office may need 100 kW of backup, a shopping centre or office tower several hundred kilowatts, and a large mixed-use development or hospital campus 2,000 kW or more. MPMC's generator set range, from 9 kVA to 3,750 kVA, covers every one of these bands with open, economic, silent and containerised designs, so building owners and MEP contractors can match each project with the right size and enclosure.
Smaller buildings typically use canopy-type sets. MPMC's SE economic series offers a cost-optimised option, while the SR rental type and SR2 silent type, with noise reduction of up to 35 dB(A), suit sites near residents, guests and patients. Compact footprints make them easy to place in service yards or car parks.
Engine choices in this band include Perkins, Cummins, Kubota, Yanmar and other partners, so building owners can match the set to local service support, and every model is available with automatic mains changeover for unattended operation.
Mid-size buildings such as hotels, offices and retail centres often choose a single silent set in this band. MPMC's SR2 Series includes 1,000 kVA silent sets built around Perkins engines and Stamford alternators, combining high output with an enclosure designed for urban locations.
Large developments use containerised units, either singly or in parallel. MPMC's Cummins-documented models run from 1,000 kVA on the KTA38-G5 to 2,000 kVA on the QSK60-G4 at 50 Hz, and super-silent SC containers achieve noise levels as low as 83.4 dB(A) at 1 m and 75% load on the MCLS1250 SC.
Parallel systems let a building add capacity in stages as tenants move in, and provide N+1 redundancy so one unit can be serviced while the others stand ready. Motorised breakers from ABB or Schneider and DEIF or DSE synchronising controllers keep switching smooth and automatic. At the upper end of the range, MPMC's containerised two-engine units, from 1,250 kVA to 3,000 kVA with Baudouin, Scania or Perkins engines and Stamford or Leroy-Somer alternators, give large developments a further containerised option.
MPMC SR2 Series 1,000 kVA silent generator set with a Perkins 4008TAG2A engine and Stamford alternator.Table 1. MPMC generator sets by commercial building power band
| Power band | Typical building | MPMC series | Key feature |
|---|---|---|---|
|
100-500 kW |
Small hotels, offices, clinics |
SE, SR, SR2 |
Compact; silent options |
|
500-1,000 kW |
Hotels, offices, retail centres |
SR2 silent |
High output in a quiet enclosure |
|
1,000-2,000 kW |
Shopping centres, office towers |
SC containerised |
Super-silent; parallel-ready |
|
2,000 kW and above |
Mixed-use developments, hospital campuses |
Parallel SC units |
N+1 redundancy; scalable |
Commercial buildings need backup power that starts automatically and runs quietly. DSE or DEIF controllers handle automatic mains changeover and parallel load sharing, and steady-state frequency stability within ±0.25% with voltage regulation within ±1% protect lifts, building management systems and IT. Fuel tank options of 6, 8, 12 or 24 hours, plus bonded or external tanks, match each building's autonomy requirement.
On a 3 MW commercial building project in New Zealand, MPMC supplied four 750 kVA units powered by Doosan DP222LC engines with Stamford S5L1D-H4 alternators, housed in 20HC super-silent containers rated at 75 dB(A) at 7 m and full load, with DSE8610 load sharing, ABB 1,250 A motorised breakers and 9 kW engine block preheaters for reliable starting.
Engine compartment of an MPMC 20HC super-silent generator set from the 3 MW commercial building project in New Zealand.Table 2. MPMC references in commercial and public buildings
| Project | Capacity | Configuration |
|---|---|---|
|
Commercial buildings, New Zealand |
3 MW |
4 x 750 kVA Doosan DP222LC; 20HC super-silent, 75 dB(A) at 7 m |
|
Hospital critical load backup, New Zealand |
4 MW |
Perkins 4016-61TRG3; 40HC super-silent, 85 dB(A) at 1 m |
|
Hospital backup, China |
3 MW |
2 x 1,500 kVA Perkins 4012-46TAG2A |
|
Stadium, Mexico |
6.9 MW |
5 x 1,375 kVA Cummins KTA50-G3; 60 Hz / 440 V; ATS cabinet |
|
Municipal electricity backup, Libya |
2.4 MW |
Perkins 4012-46TAG2A + Stamford S7L1D-C41 |
Every unit is load-tested from 0% to 110% in MPMC's CNAS-accredited test centre, and buildings with solar ambitions can add HBD battery storage to reduce generator set running time and support peak shaving. Commercial and industrial battery storage also provides load support and smooths load fluctuations, so storage and generator sets complement each other.
Containerised and silent units are fabricated with laser cutting, certified welding and C3 to C5 anti-corrosion coating, so enclosures stay presentable in service yards and car parks for years, and remote monitoring options let facility managers check status from the building management office.
• Define the essential loads: lifts, life safety, IT, HVAC
• Note noise limits and the available installation space
• Set the required run time and fuel arrangement
• Decide between a single set and parallel units