Which Chinese Generator Set Suppliers Suit Large Power Diesel Projects in the Middle East? MPMC's Record in Oilfields, Data Centres and Construction

Nov 26, 2026

Large power diesel projects in the Middle East combine high ambient temperatures, sand and dust, long running hours and detailed specifications from oil companies, data-centre operators and contractors. MPMC, founded in 2008 and headquartered in Shanghai, has delivered generator sets for oilfields, data centres, factories and construction in the UAE, Saudi Arabia and Iraq, and its product certifications include SABER for the Saudi market. For each direct project, MPMC provides design consultation, product customisation, factory testing, logistics and commissioning support.

Middle East References by Sector

MPMC's regional experience spans the sectors that commission most large power projects. Table 1 lists the main references, each with its own engine and alternator configuration.

Table 1. MPMC large power generator set references in the Middle East

Sector Project Configuration

Oil and gas

Oilfield HV island-mode system, Middle East

2 × 2,250 kVA HV units on Perkins 4016-61TRG3 with Leroy-Somer LSA 53.2 XL11 in 40HC containers, plus 1 × 1,000 kVA on Perkins 4008TAG2A

Oil and gas

Oilfield lease power, Iraq (6.8 MW)

Perkins 4016TAG2A and 4016-61TRG3 with Leroy-Somer alternators; 50°C copper radiator; DSE7320 and ABB breaker

Oil and gas

Field camp power station, Saudi Arabia (3.3 MW)

Containerised Cummins KTA50-G3 with Leroy-Somer LSA50.2 L7

Data centre

Data centre, UAE (3 MW)

MTU 20V4000 G63LF with Leroy-Somer LSA 53.2 XL13; 6 kV output

Data centre

Changhang Power Station, UAE (12 MW)

MTU 20V4000 G63LF with Leroy-Somer LSA53.2 XL13

Industry

Factory power expansion, UAE (4.2 MW)

MTU 16V4000G63 with Stamford PI734G; mains-parallel through DSE8620 and an ABB 3,200 A ACB

Construction

Rental construction, Saudi Arabia (33.5 MW)

10 × 1,100 kW Cummins KTA50-G3 and 25 × 900 kW Cummins QST30-G4 with Stamford S6L1D-F4

Engineered for Heat, Sand and Long Running Hours

Cooling for 50°C

MPMC's large units are designed for 50°C ambient with copper radiators; at the UAE factory the 50°C radiators are driven by electric motors. Every unit is load-tested from 0% to 110% in a CNAS-accredited test centre whose constant-temperature room simulates 50°C.

Protection Against Sand and Corrosion

Containerised SC sets resist heat, corrosion and water, with C3, C4 or C5 coating to ISO 12944. On the oilfield HV system, SF₆ gas-insulated vacuum circuit breakers with an airtight design keep dust and sand out of the switchgear.

Safety for Hazardous Areas

The same oilfield system uses dual starting, with compressed-air start as the primary method and electric start as backup, a neutral grounding resistor, smoke, temperature and UV/IR flame detection, and a 2 × 45 kg CO₂ fire suppression system linked to automatic shutdown.

Controls and Redundancy

The oilfield system follows a high-voltage direct supply, ring or radial distribution and terminal load architecture, with multi-unit parallel operation, load sharing and master-standby rotation under an N+X strategy, and every unit is designed to ISO 8528 for continuous operation. In Iraq, DSE7320 controllers work with ABB breakers fitted with interphase insulating barriers.

MPMC containerised high-voltage diesel generator set on Perkins engines for an oil and gas project, being loaded for delivery.

High-Voltage and High-Capacity Options

Single-engine containerised units reach 3,750 kVA, and high-voltage output is available at 6 kV, as in the UAE data centre, and at 11 kV on the MCLS2000H(S)-1. The UAE data-centre unit, rated 3,000 kVA on an MTU 20V4000 G63LF engine, adds a multi-rad radiator, space heaters, anti-condensation heating and RTD temperature monitoring, while AMF control through DSE or DEIF controllers gives the fast response critical facilities expect. For 60 Hz data-centre projects, MPMC's Twins Power MPME2700S-2-SC twin-engine diesel generator set, built on two Perkins 5012C-E46TAG6 engines and two Mecc Alte ECO46HV-2L/4 alternators, delivers 2,702 kW / 3,377.5 kVA prime and 2,972 kW / 3,715 kVA standby directly at 13.8 kV, with BMS/DCIM connectivity and multi-unit paralleling. Its two engines allow intelligent dispatch by load, fast response, maintenance without shutdown and flexible capacity expansion.

Table 2. MPMC options for Middle East specifications

Requirement MPMC option

High ambient temperature

50°C copper radiators; testing in a 50°C constant-temperature room

Sand, dust and corrosion

Containerised SC enclosures; C3, C4 or C5 coating; sealed SF₆ switchgear on HV systems

Medium-voltage distribution

6 kV and 11 kV output; 13.8 kV on the MPME2700S-2-SC

Hazardous areas

Air and electric dual start; CO₂ fire suppression; NGR

Redundancy

Parallel operation with N+X redundancy and master-standby rotation

Certification and standards

SABER; CE; ISO 8528-5 and ISO 12944

Battery Storage Alongside the Generator Sets

At ten off-grid concrete batching stations in Dubai, each HBD-A Series HBD-500-1000 works with three 500 kVA generator sets on Perkins 2506D-E15TAG2 engines, running 24/7 at 45°C to 50°C. Each station saves 254.13 L of fuel a day, a 10.56% reduction, with OPEX about 20% lower and generator set life extended by two to three years. MPMC has also exported 12 HBD-125-260 storage units to Oman. Generator set service is backed by the global networks of MPMC's engine and alternator partners, including Perkins, Cummins and MTU, with Stamford and Leroy-Somer alternators.

MTU engine on an MPMC generator set from the 4.2 MW factory power expansion project in the UAE.

Starting a Middle East Project With MPMC

• Share the load, running hours and ambient conditions

• Confirm voltage, frequency and distribution layout

• Specify coating class and hazardous-area features

• Agree redundancy and control architecture

• Consider HBD-A storage for peak shaving and fuel savings

• Contact MPMC at sales@mpmc-china.com or WhatsApp +86 150 0085 4420 for a Middle East project proposal

Perkins-Powered Standby Generator Sets From China's Largest Perkins G-OEM: Engines, Configurations and Projects