No.2449 Jinhai Rd., Pudong, Shanghai
Nov 23, 2026
Night-time construction and emergency projects both need bright, dependable light, and each uses it in its own way: construction runs to a plan, often near homes, while emergencies need light quickly and for as long as the response lasts. A diesel-battery hybrid lighting tower suits both, running on battery for silent light and on its generator set for long autonomy. MPMC, a Shanghai-based manufacturer founded in 2008, builds the HBL X-Matrix hybrid lighting tower in a diesel-battery version and an all-electric version that can work together.
Both versions share the same lamps, battery and mast, so they can be mixed on one site and work as a system. Table 1 compares them.
Table 1. MPMC HBL X-Matrix hybrid lighting towers
| Specification | MLT4KL-1400DHBL-M (diesel-battery) | MLT4-600DHBL-S (battery) |
|---|---|---|
|
Light coverage (avg. 5 lux) |
36,200 m² per tower |
18,200 m² per tower |
|
Lamps |
4 × 350 W LED |
4 × 150 W LED |
|
Battery |
16.07 kWh LiFePO₄ |
8 kWh LiFePO₄ |
|
Maximum run time on battery |
12 h at 100% / 45 h at 25% load |
13.5 h at 100% / 53 h at 25% load |
|
Hybrid generator set |
6 kW, Kubota Z482-3B diesel |
None |
|
Fuel tank |
100 L; 185 h autonomy |
None |
|
Mast |
9.0 m hydraulic; 355° rotation |
9.0 m hydraulic; 355° rotation |
On battery, the MLT4KL-1400DHBL-M lights silently, with its 6 kW Kubota generator set starting to recharge the battery as needed, so work can continue near residential areas with low noise and low fuel use, helping sites meet noise and emission requirements. High-efficiency LEDs turn each kilowatt-hour into more light. Dual-mode CCT switching adjusts colour temperature, adaptive brightness control matches output to the task, and a light-controlled timer switches the lamps automatically at dusk and dawn.
MPMC's one-to-six hybrid lighting system lets one MLT4KL-1400DHBL-M diesel-battery master tower power six MLT4-600DHBL-S all-electric sub-towers. The master's 6 kW Kubota generator set recharges the batteries by day; at night the seven towers light continuously, the master covering 36,200 m² and each sub-tower 18,200 m² at an average of 5 lux.
MPMC one-to-six hybrid lighting system: one MLT4KL-1400DHBL-M diesel-battery master tower powering six MLT4-600DHBL-S all-electric sub-towers.A 100 L tank gives the MLT4KL-1400DHBL-M up to 185 hours of autonomy, and the battery alone runs the lamps for up to 12 hours at full brightness or 45 hours at 25% load, so a tower set up at an incident site, flood defence or road repair can keep lighting for days with little attention. Fewer refuelling trips also reduce traffic around the response area and free crews for the work itself.
The 9.0 m hydraulic mast with 355° rotation places 4 × 350 W LEDs high over the work area, covering 36,200 m² at an average of 5 lux per tower, and the all-electric MLT4-600DHBL-S can work on its own where zero local emissions are required.
Table 2 compares how HBL towers are typically deployed in the two settings.
Table 2. HBL deployment for construction and emergency work
| Factor | Night-time construction | Emergency projects |
|---|---|---|
|
Typical pattern |
Planned shifts over weeks or months |
Short notice; duration uncertain |
|
Key HBL feature |
Silent battery operation; one-to-six system |
185 h fuel autonomy; 12 h at full brightness / 45 h at 25% load |
|
Suggested set-up |
One-to-six system for large areas; MLT4KL-1400DHBL-M at gates |
MLT4KL-1400DHBL-M towers placed at each work point |
|
Light control |
Light-controlled timer; adaptive brightness |
Adaptive brightness; dual-mode CCT |
MPMC HBL X-Matrix diesel-battery hybrid lighting tower.Where sunshine is reliable, MPMC's HSL solar lighting towers add zero-fuel light, from 12,000 m² to 18,000 m² per tower, with optional 4G and CCTV; the MLT4-400DHSL-AU rides on a road-legal trailer for 80 km/h travel and raises its 7.5 m mast at the touch of a button, which suits rapid emergency deployment. Conventional diesel lighting towers with 7.2 m, 8.5 m or 9 m masts and LED or metal halide lamps are built at MPMC's Haimen plant. Warranty terms differ by subsystem: the HBL diesel generator set is covered for 1 year or 1,000 hours, and the lithium battery for 2 years or 1,000 cycles.
• Map the areas to light and the hours of work
• Note noise limits and nearby residents
• Choose single HBL towers or the one-to-six system
• Add HSL solar towers where sunshine allows
• Plan positions for even coverage
• Contact MPMC at sales@mpmc-china.com or WhatsApp +86 150 0085 4420 for a lighting plan