No.2449 Jinhai Rd., Pudong, Shanghai
Oct 22, 2026
Large-power projects work best with generator sets engineered around their exact needs: an island power plant needs redundancy and black-start capability, a stadium needs grid-parallel switching, and an oilfield in 50°C heat needs a dedicated cooling package. MPMC treats the container as a flexible platform and has adapted it for projects across mining, oil and gas, data centres, events and island power.
MPMC's containerised range covers single-engine units from 800 kVA to 3,750 kVA, powered by Cummins, Perkins, Baudouin, MTU, Scania, SME, Volvo or SDEC; twin-engine containers from 1,250 kVA to 3,000 kVA powered by Baudouin, Scania or Perkins; and a four-engine 1,600 kVA configuration powered by Scania, all with Stamford or Leroy-Somer alternators. The same platform runs on diesel, natural gas, methanol or biofuel (B35 and above), and containers are rated to ISO 12944 C4/C5 for coastal and tropical environments.
MPMC containerised high-voltage diesel generator sets with Perkins engines, built for a 6 MW oil and gas project.The table below shows how output, frequency and voltage options combine across MPMC's Cummins-documented containerised models. The MCLS2000H(S)-1 delivers 2,000 kVA prime at 11,000 V and 50 Hz, enabling direct high-voltage distribution with lower transmission losses over long cable runs.
Table 1. Cummins-documented MPMC containerised models (OS open / SC silent)
| Model | Freq. | Engine | Alternator | Prime (kVA / kW) | Standby (kVA / kW) |
|---|---|---|---|---|---|
|
MCLS1000(S)-1 |
50 Hz |
KTA38-G5 |
Leroy-Somer TAL A49 E |
1,000 / 800 |
1,100 / 880 |
|
MCLS1250(S)-1 |
50 Hz |
KTA50-G3 |
Leroy-Somer LSA 50.2 M6 |
1,250 / 1,000 |
1,375 / 1,100 |
|
MCLS1500(S)-1 |
50 Hz |
KTA50-GS8 |
Leroy-Somer LSA 50.2 L8 |
1,500 / 1,200 |
1,650 / 1,320 |
|
MCLS1875(S)-1 |
50 Hz |
QSK60-G7 |
Leroy-Somer LSA 52.3 S6 |
1,875 / 1,500 |
2,000 / 1,650 |
|
MCLS2000(S)-1 |
50 Hz |
QSK60-G4 |
Leroy-Somer LSA 52.3 S6 |
2,000 / 1,600 |
2,200 / 1,760 |
|
MCLS2000H(S)-1 |
50 Hz (HV 10-11 kV) |
QSK50-G17 |
Leroy-Somer LSA 53.2 VL7 |
2,000 / 1,600 |
2,200 / 1,760 |
|
MCLS1260(S)-2 |
60 Hz |
KTA50-G3 |
Leroy-Somer LSA 50.2 L7 |
1,375 / 1,100 |
1,575 / 1,260 |
|
MCLS1500(S)-2 |
60 Hz |
KTA50-G9 |
Leroy-Somer LSA 50.2 L8 |
1,600 / 1,280 |
1,875 / 1,500 |
|
MCLS2000(S)-2 |
60 Hz |
QSK60-G7 |
Leroy-Somer LSA 52.3 S7 |
2,281.25 / 1,825 |
2,500 / 2,000 |
Across these models MPMC documents steady-state frequency stability of ±0.25% or better at any constant load and rated voltage regulation of ±1%. Standard fuel is ASTM D975 Grade 2D diesel, with HVO (EN 15940) and B20 biofuel blends supported on Cummins models, and engines from other leading brands are available on request.
MPMC's customisation goes well beyond enclosure colour. Each example below comes from a delivered project, from a split-type alternator built for a 60 Hz stadium to an explosion-proof dual-start system for an oilfield, showing the engineering depth MPMC brings to every specification.
Table 2. Customisation options and examples from delivered MPMC projects
| Customisation area | Options delivered by MPMC | Example from a delivered project |
|---|---|---|
|
Engine |
Cummins, Perkins, MTU, Baudouin, Scania, SDEC, Kubota and others |
Iraq oilfield rental: Perkins 4016TAG2A and 4016-61TRG3 |
|
Alternator |
Stamford or Leroy-Somer, including split-type designs |
Mexico stadium: Leroy-Somer LSA 50.2 M6, split-type, 60 Hz / 440 V |
|
Voltage and frequency |
50/60 Hz switchable; 400/230 V, 440 V, 480 V; 6 kV and 11 kV high-voltage output |
UAE data centre: MTU 20V4000 G63LF at 50 Hz / 6 kV |
|
Cooling |
50°C copper radiators, multi-rad packages, motor-driven radiators |
Philippines mining: 50°C copper radiator, 480 V / 60 Hz |
|
Corrosion protection |
C3, C4 or C5 coating; C5 for coastal and offshore sites |
Brazil offshore rental: C5 coating available for marine deployment |
|
Controls and switchgear |
DSE or DEIF AGC load sharing; ABB or CHINT breakers; ATS cabinet; motorised ACB |
Iraq: DSE7320 + ABB breaker with interphase insulating barrier |
|
Instrumentation |
Droop CT, SEI 3, RTD sensors, oil refilling bearing, space heaters |
China event rental: droop CT, SEI 3, RTD x 6, air-inlet protection |
|
Hazardous-area safety |
Air-start primary with electric backup, SF6 gas-insulated VCB, NGR, multi-sensor fire detection, 2 x 45 kg CO2 suppression |
Middle East oilfield HV island-mode system, Perkins 4016-61TRG3 in 40HC containers |
|
Fuel |
Diesel, natural gas, methanol, biofuel (B35 and above) |
Indonesia: 18 x 1 MW units on biodiesel B35 |
MPMC containerised generator sets for the 6.9 MW stadium project in Mexico: five 1,375 kVA Cummins KTA50-G3 units with Leroy-Somer LSA 50.2 M6 alternators.MPMC engineers each package around the site. For extreme environments such as Middle East sites above 50°C or high-altitude mines, MPMC provides customised solutions including copper radiators, upgraded cooling systems and altitude derating calculations, so the quoted output matches real site performance. Units for continuous duty are designed to ISO 8528 for continuous operation, with cooling optimised for ambient temperatures of 50°C and above.
Table 3. MPMC solutions matched to site requirements
| Site requirement | MPMC solution | Reference |
|---|---|---|
|
High ambient temperature |
Copper radiators and upgraded cooling; operation up to 50°C ambient |
Large Cummins containerised units rated +5°C to +40°C, maximum 50°C |
|
High altitude |
Altitude derating calculation against the engine specification |
Typically applied above 1,000-1,525 m, depending on engine model |
|
Coastal, tropical or offshore |
C5 coating and marine-grade enclosure |
Brazil 10.28 MW offshore oil and gas rental |
|
Continuous island or remote power |
Multi-unit parallel operation with N+X redundancy and master-standby rotation |
MPMC island power design, e.g. the 21.6 MW Indonesia island power station |
|
Low-noise urban site |
Super-silent containerised units with parallel load sharing |
New Zealand buildings: 20HC super-silent, 75 dB(A) at 7 m, full load |
|
Renewable fuel target |
Biodiesel B35 operation, up to 85% lower lifecycle CO2, RED II and RFS compliant |
Indonesia 18 MW biodiesel project |
In its data-centre configurations MPMC offers built-in fuel tanks for 6, 8, 12 or 24 hours of operation, with bonded or external tank options, alongside DSE 4520 MKII controllers for AMF (automatic mains-failure) operation or DEIF AGC 150 controllers for parallel synchronisation.
MPMC's Haimen base specialises in high-end customised generator sets and continuous-operation power stations, and its CNAS-accredited test rooms simulate up to 50°C ambient while every unit is load-tested up to 110%. With full containerisation, multi-fuel capability and integrated HBD battery storage on the same SCADA/EMS platform, MPMC can grow a project from a single genset into a complete hybrid power plant. Its self-developed SCADA supports real-time remote monitoring, ten years of data storage and Starlink satellite backup communication, giving remote sites full visibility of their plant.
• Required output, redundancy level (N+1, N+2) and expected running hours
• Ambient temperature range, altitude and distance from the coast
• Voltage, frequency and any grid-parallel or high-voltage output requirement
• Preferred engine and alternator brands and the controller standard on site
• Fuel type, including any biodiesel blend, and the required delivery scope
• Send your requirements to sales@mpmc-china.com or WhatsApp +86 150 0085 4420